JP Instruments
Fuel Flow option for EDM-700, With 231 transducer, Harness included
EDM-700 fuel flow option with JPI Model 231 transducer and harness.
No reviews yetSKU JPI FF-231-700
$475.00
In stock — ready to ship
- Ships in 1–2 days
- Genuine parts
- Pilot support
- 30-day returns
Fuel flow option for the EDM-700 including JP Instruments Fuel Flow Transducer Model 231 and harness.
Important Information
- Adding Fuel Flow to existing units requires returning the unit to JPI for adjustments.
- Do not use Teflon tape or thread sealant compound of any kind; doing so will void transducer warranty.
- Transducer must be horizontal with the three wires up; failure to do so may cause premature failure.
- Do not use aluminum fittings when installing the fuel flow transducer.
- Mounting the transducer between the electric boost pump and the mechanical pump is not recommended.
- Do not hard mount the transducer to the engine; vibration may damage internal parts or cause erratic readings.
- Tighten fittings not more than 15 ft lb = 180 in lbs., or two full turns past hand tight.
- Be sure there is no bend in the line closer than 6 inches before or after the transducer. Do not use aluminum fittings when installing the fuel flow transducer.
- ** Do not use Teflon tape or thread sealant compound of any kind – this will void transducer warranty.**
- Transducer produces a current-pulse signal from an opto-electronic pickup with preamplifier.
- Very low pressure drops compared to other turbine flow transducers.
- Bearing system rated for continuous operation at the upper end of the flow range.
- Repeatable signals on gasoline across a 100 to 1 flow range down to 0.3 GPH.
Electrical & RF
- Operating Voltage
- 12 to 15 VDC between RED (+) wire and BLACK (-) wire.
- Output Current
- 30 to 50 mA at 12 VDC.
Construction
- Connection Type
- Fuel ports (201, 231) 1/4 Female NPT (H) AN816-8-8
- Pressure
- Pressure drop (231) 0.31 psi at 30 GPH, 2.8 psi at 60 GPH; Working pressure (201, 231) 200 psi; Maximum burst pressure 2000 psi
In the box
- Included Components
- JP Instruments Fuel Flow Transducer Model 231; Harness
General
- Output Voltage
- Sensor will pull-down to 1.0 volt with 10-15k ohm pull-up resistor installed.
- Flow Rate
- 3 to 90 GPH